wiring has been cut or otherwise does not form a complete loop. This will
only occur if the system has been programmed for Double End-of-Line
Resistor Zone operation.
• “Trbl” indicates the zone is presently in a trouble condition. This means that
the zone wiring has been cut or otherwise does not form a complete loop.
The condition will only occur for Supervisory Zones (such as 24-Hour Fire,
Delayed Fire, Auto-Verify Fire and LINKS Supervisory zones).
PC4020 and PC4010 v2.x:
• “O” indicates the zone is presently secure
• “S” indicates the zone is presently faulted (shorted). This will only occur if
the zone is using Double End of Line Resistor Zone Operation.
• “T” indicates the zone is presently in a tampered condition. This
means the zone wiring has been cut or otherwise does not form a
complete loop.
• “V” indicates the zone is not secure.
• “R” indicates the zone is presently in a Trouble condition. This
means that the zone wiring has been cut or otherwise does not
form a complete loop. The condition will only occur for Supervisory
Zones (such as 24-hour fire, Delayed fire, Auto-Verify fire, and
Links Supervisory Zones).
• “F” indicates that a wireless RF zone is not communicating with
the panel.
• “L” indicates that a wireless RF zone's batteries are low and need
to be replaced.
• “M” indicates that a wireless RF zone has been tampered with and
removed from it's backplate.
PC5015, PC5010, PC5008, PC1575/1580, PC1565-2P, PC1555/1565
and PC580/585:
• “OK” indicates the zone is presently secure.
• “Open” indicates the zone is not secure.
• “Tmpr” indicates the zone is presently in a tampered condition.
This means the zone wiring has been cut or otherwise does not
form a complete loop.
• “Fault” indicates the zone is presently faulted (shorted).
• “LoBat” indicates that a wireless RF zone's batteries are low and
need to be replaced (PC5015, PC5010, PC5008, PC1565-2P,
PC1555/1565 and PC580/585).
• “• •” indicates the zone does not exist or is not enrolled.
• Arm/Disarm
Uploads the armed status of each partition.
• “No” indicates the partition is disarmed
• “Yes” indicates the partition is armed.
• Alarm Memory
Uploads the Alarm Memory Status of each zone.
• “Yes” indicates the zone was in alarm during last armed period
• “No” indicates the zone was not in alarm
• Bypass Zones
Uploads the bypass status of each zone. This does not include Home-Away
zones that were bypassed automatically; only manually bypassed zones are
displayed.