40
Upload Window Contents
This selection appears in the place of the “Upload Entire Panel / Upload Entire Module
Info” section on the DUC menu if you are editing one of the individual windows in the
tree menu. This function will allow you to upload only the contents of the window that
you are currently in. Certain windows, such as the File Information window, are for
clarification of the Work Files and cannot be uploaded or downloaded.
Download Window Contents
This function will download only the contents of the window you are currently in.
Keypad toggles, function keys and options will be sent to
allall
allall
all keypads on the system.
Print All Screens (PC5015, PC5010, PC5008, PC4020 v2.x,
PC4010 v2.x, PC4000, PC1575/1580, PC1565-2P, PC1555/1565
and PC580/585 only)
This function will print all programming information for all sections of the selected file.
If you choose to print to a file, the text file will be in the WF directory with the filename
extension .PRN for panel files and .PRT for Escort files.
NOTE: After Print Screens is selected, a second menu will be displayed with the
following options: “Send Output to File” will print all screens to an ASCII file with the
same name as the account file with .PRN as the extension. “Send Output to Printer”
will print to the printer selected in the program configuration.
Print Selected Screens (PC5015, PC5010, PC5008, PC4020,
PC4010, PC4000, PC1575/1580, PC1565-2P, PC1555/1565 and
PC580/585 only)
This function will print all programming information for selected windows within a
file. To select a window for printing, press [CTRL][P] while the window is displayed.
When “Print Selected Screens” is selected, all windows tagged with the [CTRL][P]
command will be printed. To deselect a window, press [CTRL][P] again while the
window is displayed.
If you choose to print to a file, the text file will be in the WF directory with the filename
extension .PRN for panel files and .PRT for Escort files.
Clear Print Tags
This function will clear all of the print tags that have been selected to be printed.
Enable Modem / PC-Link (PC5015, PC5010, PC5008, PC1575/
1580, PC1565-2P, PC1555/1565 and PC580/585 only)
This function will toggle the communications mode between using a modem link
and PC-Link.
Initialize Modem
This function will re-initialize the modem to the current defaults, including the
settings entered into the Modem Command File (MODEMSTR.FIL). This is useful if
the connection with the panel has been broken (e.g. if the modem power cord
became unplugged) and the software is unable to automatically re-initialize the
modem . When you have fixed the problem, making this selection should re-initialize
the modem, allowing you to reconnect to the panel.