P R O G R A M D E S C R I P T I O N S
When power is applied to the panel, downloading
will be enabled for six hours. This will allow you to
perform downloading without having to do any
keypad programming.
If the Downloading Answer option is enabled, or during the
first six hours after power up, the panel will answer calls for
downloading when the programmed Number of Rings is
heard by the panel.
If the Answering Machine Override option is enabled (or
during the first six hours after power up), the panel will
answer incoming calls for downloading in the following
manner:
1. The panel hears one or two rings then misses a ring.
2. At this point the panel will start a timer.
3. If the panel hears another ring before the
Answering Machine Double-Call Timer expires, it
will answer on the first ring of the second call.
The panel will immediately go on line and begin downloading.
If the Call-Back option is enabled, the panel and the computer
will both hang up. The panel will then call the Downloading
Computer’s Telephone Number and wait for the computer
to answer. Once the computer answers, downloading will
begin.
If the User Enabled DLS Window for One Hour option is
ON, the user can activate the downloading feature for one
hour by entering [
] [6] [Master Code] [5]. After one hour,
the panel will not answer incoming calls unless the
Downloading Answer option is enabled.
The Download Access Code and Panel Identifier Code are
for security and proper identification. Both the panel and the
computer file should contain the same information programmed
before attempting to download.
The time to complete a successful download can be
significantly reduced with the use of the PC-LINK. This
adaptor will allow on-site downloading of supported panels to
occur. To Initiate Local Downloading via the PC-LINK,
enter [
] [8] [Installer’s Code] [77] [Installer’s Code] [77].
Downloading can also be performed through the LINKS 1000
cellular communicator if the phone line is disconnected. If
Call Back is being used, you may have to program the LINKS
1000 Preamble to have the panel call the computer correctly.
When a Zone Status Upload is performed through
PC-Link, the information uploaded may not be
accurate. For more information refer to the Download
Manual included with the computer software.
Downloading Answer ..................... Section [71], Option [1]
Number of Rings ................................................Section [70
]
Answering Machine Override........ Section [71], Option [6]
User Enable DLS Window for One Hour ........ Section [71],
Option [2]
Call-Back ........................................ Section [71], Option [3]
Answering Machine Double Call Timer .......... Section [75]
Download Computer Telephone Number....... Section [72]
Download Access Code .................................. Section [73]
Panel Identification Code ................................ Section [74]
Initiate Local Downloading (PC-LINK) ............ Section [77]
LINKS 1000 Preamble (Downloading) ............. Section [79]
5.10 Telephone Line Monitor (TLM)
The panel will supervise the presence of the phone line and
will indicate a trouble condition if the phone line is
disconnected. If the TLM Enabled option is selected, the
panel will wait for the TLM Trouble Delay time period before
indicating the trouble so that a momentary interruption of the
phone line will not cause a trouble condition.
If the TLM Trouble Only option is enabled, the panel will
indicate a TLM trouble only at the keypad if the system is
armed. To activate the bell output in the case of a TLM
trouble while the system is armed, the Audible When
Armed option must be selected.
When the trouble condition is restored, the panel can send
a TLM Restoral Reporting Code. Any events which occur
while the phone line is down will also be communicated.
If the LINKS 1000 Cellular Communicator is being used, the
panel can be programmed to report a TLM Trouble
Reporting Code.
TLM Enable/Disable
.......................
Section [08], Option [5]
TLM Trouble Only or
Audible When Armed .................... Section [08], Option [6]
TLM Trouble Reporting Code
..........................
Section [43]
TLM Restoral Reporting Code
.........................
Section [44]
TLM Trouble Delay
..........................
Section [62], Option [1]
5.11 Siren Supervision
The panel supervises the Bell output. If an open condition is
detected or if the fuse is blown, the panel will immediately
indicate a trouble condition by beeping the keypad twice
every 10 seconds to alert the owner of the problem. The
panel can send a Bell Circuit Trouble Reporting Code
immediately. Once the problem is corrected, the panel can
send a Bell Circuit Trouble Restoral Reporting Code.
Bell Circuit Trouble Reporting Code ............... Section [43]
Bell Circuit Trouble Restoral Reporting Code Section [44]
5.12 Test Transmission
To ensure that the communication link with the central
station is functioning properly, the panel can be programmed
to send a test transmission signal on a regular basis.
The panel can send a Periodic Test Transmission
Reporting Code at the programmed Test Transmission
Time of Day. The Test Transmission Cycle determines the
number of days (001 to 255) between tests. If the test
transmission cycle being programmed is of a lesser value
than the previous value, the system will wait the original
period before the next test transmission is sent, and then
begin reporting with the new interval.
The panel can also send a test for the LINKS 1000 Cellular
Communicator, if being used. If the LINKS 1000 Test
Transmission Code is programmed, the panel will send a
cellular test at the same time as the land line test transmission.
The end user can generate a communicator test. If the
System Test Reporting Code is programmed, the panel
will send the signal when the System Test keypad command
is entered
(see Section 3.4 – “[(see Section 3.4 – “[
(see Section 3.4 – “[(see Section 3.4 – “[
(see Section 3.4 – “[
] Commands; [] Commands; [
] Commands; [] Commands; [
] Commands; [
] [6] User] [6] User
] [6] User] [6] User
] [6] User
Functions”).Functions”).
Functions”).Functions”).
Functions”).