[10] 24 Hour Supervisory Buzzer Zone
If this zone is violated when the system is either armed or
disarmed, the panel will immediately latch the keypad
buzzer until a valid user code is entered and will immediately
communicate to the central station.
[11] 24 Hour Burglary Zone
If this zone is violated when the system is either armed or
disarmed, the panel will immediately latch the alarm output
and communicate to the central station. The alarm will
sound for the Bell Cutoff time programmed in Section [02]
(“System Times”) or until a valid user code is entered.
[12] -[20]
The following zone definitions operate similar to the 24 Hour
Burglary except for the System Event output type and the
SIA identifier:
[12] 24 Hour Heat Zone [17] 24 Hour Intrusion
[13]
Not Used
Emergency Zone
[14] 24 Hour Holdup Zone [18] 24 Hour Sprinkler Zone
[15] 24 Hour Auxiliary Zone [19] 24 Hour Water Flow Zone
[16] 24 Hour Panic Zone [20] 24 Hour Freezer Zone
[21] 24 Hour Latching Tamper
If this zone is violated, the installer must enter Installer’s
Programming before the system can be armed.
5.35.3
5.35.3
5.3
Zone AttributesZone Attributes
Zone AttributesZone Attributes
Zone Attributes
All zones, with the exception of 24 Hour and Fire,
have an exit delay. When the system is armed, the
zones may be violated during the exit delay without
causing an alarm.
Attributes for Fire Zones should not be changed
from the default settings.
Additional zone attributes can be programmed to customize
the operation of a zone for a specific application. The
following attributes are programmable for each zone:
• Audible / Silent – This attribute determines whether or not
the zone will activate the alarm output.
• Pulsed / Steady – This attribute determines whether the
alarm output will be steady or will pulse ON and OFF every
second.
• Activate Chime – This attribute determines whether or
not the zone will activate the chime feature
(see Section(see Section
(see Section(see Section
(see Section
3.4 – “[3.4 – “[
3.4 – “[3.4 – “[
3.4 – “[
✱✱
✱✱
✱
] [4] Door Chime On/Off”).] [4] Door Chime On/Off”).
] [4] Door Chime On/Off”).] [4] Door Chime On/Off”).
] [4] Door Chime On/Off”).
• Bypass Enable – This attribute determines whether or not
the zone can be manually bypassed
(see Section 3.4 –(see Section 3.4 –
(see Section 3.4 –(see Section 3.4 –
(see Section 3.4 –
“[“[
“[“[
“[
✱✱
✱✱
✱
] [1] Bypassing and Reactivating Stay/Away Zones”).] [1] Bypassing and Reactivating Stay/Away Zones”).
] [1] Bypassing and Reactivating Stay/Away Zones”).] [1] Bypassing and Reactivating Stay/Away Zones”).
] [1] Bypassing and Reactivating Stay/Away Zones”).
• Force Arm Enable – This attribute determines whether or
not the system can be armed while a zone is violated. At
the end of the exit delay, if this type of zone is violated, it
will be ignored by the panel. Once the zone is secured, it
will be monitored by the system. This zone attribute, for
example, will allow the user to arm the system with the
garage door open. Later, when the door is closed, it will be
armed along with the rest of the system.
• Downlook Activation Option (Video) – If enabled, this
attribute will activate the DLM-1/DLM-4 Downlook module.
When a given zone goes into alarm, it will activate the DLM
to take a picture of that zone.
Zones Attributes ....... Sections [21] - [26], Options [1] - [6]
5.4 Communicator – Dialing
If the Communicator Disable option is selected, the panel
will not attempt to call central station. If communication is
enabled, the panel will attempt to call central station when
an event with a valid Reporting Code occurs
(See Section(See Section
(See Section(See Section
(See Section
5.7 “Communicator – Reporting Code”). 5.7 “Communicator – Reporting Code”).
5.7 “Communicator – Reporting Code”). 5.7 “Communicator – Reporting Code”).
5.7 “Communicator – Reporting Code”).
The Communicator Call Direction Options are used to
select which phone number the panel will dial when an
event occurs.
If the DTMF Dialing option is enabled, the panel will dial
using DTMF (touch tone). If the Switch to Pulse Dial option
is enabled, the panel will switch to pulse dialing on the fifth
attempt to call the central station. When this option is
disabled, the panel will always dial using DTMF. If DTMF
Dialing is disabled, the panel will always pulse dial.
If the Busy Tone Detection option is enabled, the panel will
hang up and redial 60 seconds after having detected a busy
tone for four seconds.
The panel will attempt to send a signal to central station
eight times before indicating a Failure to Communicate
(FTC) trouble condition. The Third Phone Number can be
used as a back up for the first number in this situation
(see (see
(see (see
(see
Section 5.6 “Communicator – Phone Numbers”).Section 5.6 “Communicator – Phone Numbers”).
Section 5.6 “Communicator – Phone Numbers”).Section 5.6 “Communicator – Phone Numbers”).
Section 5.6 “Communicator – Phone Numbers”).
DTMF or Pulse Dialing ................... Section [60], Option [2]
Switch to Pulse Dialing on 5th attemptSection [60], Option [3]
Communicator Enable/Disable ..... Section [60], Option [1]
Communicator Call Direction Options Section [51] to [55]
Busy Tone Detection ...................... Section [61], Option [4]
5.5 Communicator – Account Numbers
The account number is used by the central station to
distinguish between panels. There are two account numbers
programmable for the PC1575.
First Account Code (4 digits) ........................... Section [34]
Second Account Code (4 digits) ..................... Section [35]
5.6 Communicator – Phone Numbers
The panel can use three different phone numbers for
communicating with the central station. The First Phone
Number is the primary number, the Second Phone Number
is the secondary number and the Third Phone Number will
back up the First phone number if enabled.
The Third Phone Number will NOT back up the
Second Phone Number.
If the Alternate Dial option is enabled, the panel will alternate
between the first and third phone numbers when attempting
to call the central station. If the option is disabled, the panel
will only attempt to call the Third phone number after failing
to communicate with the first phone number.
In order for Alternate Dialing to work properly, the
Third Phone Number must be enabled.