P R O G R A M D E S C R I P T I O N S
Phone numbers can be up to 32 digits which will allow you
to add special digits if required. To program the phone
number, enter the numbers 0 through 9 as required. The
following is a list of programmable HEX digits and the
function they perform:
HEX (B) - simulates the [] key on a touch tone phone
HEX (E) - forces the panel to pause for 2 seconds
HEX (C) - simulates the [#] key on a touch tone phone
HEX (F) - marks the end of the phone number
HEX (D) - forces the panel to search for dial tone
First Phone Number ......................................... Section [31]
Second Phone Number.................................... Section [32]
Third Phone Number ......................................... Section [33]
Third Phone Number Enable ......... Section [60], Option [4]
Alternate Dial .................................. Section [60], Option [5]
If no Dial Tone Detect (HEX D) is used in the phone
number, a 2-second pause (HEX E) should be
inserted.
5.7 Communicator – Reporting Codes
The panel can be programmed to report events to the
central station by sending the Reporting Code programmed
for a particular event.
Reporting codes can be one or two digits and can use HEX
digits (A through F). The following is a description of the
different Reporting Codes that can be programmed and
when the events will be reported to central station.
Reporting Codes ................................... Section [36] to [46]
5.7.1 Zone Alarm
The panel will transmit the Zone Alarm Reporting Code
when a zone goes into alarm. 24 hour type zones will go into
alarm whether the panel is armed or disarmed and report to
the central station. All other types of zones will only go into
alarm if the panel is armed. The Police Code reporting code
will be sent after 2 zones have gone into alarm within the
same armed period.
Zone Alarm Reporting Codes .......................... Section [36]
Police Code Reporting Code ........................... Section [36]
Only Zone Alarms will count towards the Police Code
5.7.2 Zone Restoral
If the Restoral on Bell Time-out option is selected, the
panel will send the Zone Restoral Reporting Code for the
zone if the alarm output times out
and
the zone is secured.
If the zone is not secured when the alarm output times out,
the panel will send the restoral immediately once the zone
is secured.
If the Restoral on Bell Time-out option is not selected, the
panel will immediately send the Zone Restoral Reporting
Code when the zone is secured, regardless of whether or not
the alarm output is active.
24 Hour type zones will report the restoral immedi-
ately once the zone is secured.
Zone Restoral Reporting Codes ... Section [37], Option [6]
Restoral on Bell Time-out .............. Section [60], Option [6]
5.7.3 Closings (Arming Codes)
The panel will transmit a Closing Reporting Code to indicate
that the system is armed. A different Reporting Code can be
transmitted for each User Code and Master Code to identify
who has armed the system.
If programmed, a Partial Closing Reporting Code will be
sent along with the Closing Reporting Code if one or more
zones were manually bypassed when the system was armed
to warn the monitoring station of a security compromise.
If the Closing Confirmation option is enabled, the keypad
will sound a series of eight beeps to confirm to the user that
the closing code was sent and received by the central station.
Closing (Arming) Reporting CodesSection [41], Option [6]
Partial Closing Reporting Code....................... Section [41]
Closing Confirmation..................... Section [61], Option [1]
5.7.4 Openings (Disarming Codes)
The panel will transmit an Opening Reporting Code to
indicate that the system has been disarmed. A different
Reporting Code can be transmitted for each User Code and
the Master Code to identify who has disarmed the system.
If the
Opening After Alarm Keypad RingbackOpening After Alarm Keypad Ringback
Opening After Alarm Keypad RingbackOpening After Alarm Keypad Ringback
Opening After Alarm Keypad Ringback option is
enabled, the keypad will emit a series of eight beeps after
an Opening Reporting Code was sent and received by the
monitoring station. If the Opening After Alarm Bell Ringback
option is enabled, the bell will squawk eight times instead of
the keypad to notify the user of a successful transmission.
The Opening After Alarm code
must
be programmed
when the Transmission Delay is being used. See
Section 5.17 “Transmission Delay”.
Opening (Disarming) Reporting Codes . Section [42], Option [6]
Opening After Alarm Keypad Ringback . Section [61], Option [2]
Opening After Alarm Bell Ringback ....... Section [61], Option [3]
5.7.5 Tampers
If the panel is programmed for Double EOL zones
(see(see
(see(see
(see
Section 2.8 – “Zone Wiring”)Section 2.8 – “Zone Wiring”)
Section 2.8 – “Zone Wiring”)Section 2.8 – “Zone Wiring”)
Section 2.8 – “Zone Wiring”)
, the panel will report a Zone
Tamper Alarm Reporting Code if an open condition is
present. A different Reporting Code can be programmed to
identify each zone. The Zone Tamper Restoral Reporting
Code will be transmitted immediately when the tamper
condition is restored.
A General System Tamper Reporting Code will be transmitted
when the tamper zone on any module is violated. The General
System Tamper Restoral Reporting Code will be transmitted
when the tamper zone on the module is restored.
Tamper Alarm Reporting Codes ...................... Section [38]
General System Tamper Alarm ........................ Section [38]
Tamper Restoral Reporting Codes.................. Section [39]
General System Tamper Restoral .................... Section [39]
5.7.6 Priority/Emergency
The panel will transmit a Keypad Fire Alarm Reporting
Code
and
the Keypad Fire Restoral Reporting Code when
Vista de pagina 15