17
P R O G R A M D E S C R I P T I O N S
the Fire Keys on any keypad are pressed for two seconds.
The panel will transmit a Keypad Auxiliary Alarm Reporting
Code
and
the Keypad Auxiliary Restoral Reporting Code
when the Auxiliary Keys on any keypad are pressed for two
seconds.
The panel will transmit a Keypad Panic Alarm Reporting
Code
and
the Keypad Panic Restoral Reporting Code when
the Panic Keys on any keypad are pressed for two seconds.
The panel will transmit a Duress Reporting Code any time
the Duress Code is entered at any keypad.
If PGM2 is being used for 2-wire smoke detectors or 24 hour
operation, the panel will send a PGM2 Alarm Reporting
Code if the zone goes into alarm
(see (see
(see (see
(see
Appendix D – “PGMAppendix D – “PGM
Appendix D – “PGMAppendix D – “PGM
Appendix D – “PGM
Output OptionsOutput Options
Output OptionsOutput Options
Output Options
”)”)
”)”)
”)
. The panel will transmit the PGM2 Restoral
Reporting Code when the zone is restored.
The above is only applicable to pulse format.
Priority Alarm and Restoral Reporting Codes Section [40]
5.7.7 Maintenance
The panel will transmit a Battery Trouble Alarm Reporting
Code when the backup battery charge drops below 11.5
V
DC. The Battery Trouble Restoral Reporting Code will not
be transmitted until the battery has been charged to over
12.5 VDC.
To prevent the panel from transmitting an AC Failure Trouble
Alarm Reporting Code during short power outages, the panel
will not send the signal unless AC power is lost for the amount
of minutes programmed for the AC Failure Communication
Delay. The AC Failure Trouble Restoral Reporting Code will
be transmitted as soon as AC power is restored.
A Bell Circuit Trouble Alarm Reporting Code will be
transmitted immediately when an open condition is measured
for the Bell Output of the main panel. The Bell Circuit
Trouble Restoral Reporting Code will be transmitted as
soon as the problem is corrected.
A Fire Trouble Alarm Reporting Code will be immediately
transmitted when an open condition is measured on any Fire
type zone
(see Section 5.2 – “Zone Definitions”). (see Section 5.2 – “Zone Definitions”).
(see Section 5.2 – “Zone Definitions”). (see Section 5.2 – “Zone Definitions”).
(see Section 5.2 – “Zone Definitions”).
The Fire
Trouble Restoral Reporting Code will be transmitted as
soon as the problem is corrected.
The Auxiliary Power Supply Trouble Alarm Reporting
Code will be transmitted if the AUX output is shorted out. The
AUX output of the control incorporates a fuseless design.
When excessive current is drawn, the panel will automatically
shut off the output. The panel will constantly check the AUX
output; when the excessive current draw is removed, the
panel will reset the output and transmit an Auxiliary Power
Supply Trouble Restoral Reporting Code.
A TLM Trouble Reporting Code can only be transmitted if a
LINKS 1000 Cellular Communicator is being used
(see(see
(see(see
(see
Section 5.23 “LINKS 1000 Cellular Communicator”)Section 5.23 “LINKS 1000 Cellular Communicator”)
Section 5.23 “LINKS 1000 Cellular Communicator”)Section 5.23 “LINKS 1000 Cellular Communicator”)
Section 5.23 “LINKS 1000 Cellular Communicator”)
. The
panel will only transmit the signal after the time programmed
for the TLM Trouble Delay. The TLM Restoral Reporting
Code will be transmitted within 10 seconds of the problem
being corrected.
A General System Supervisory Trouble Reporting Code
will be transmitted if any module goes missing from the
KEYBUS. The panel will send a General System Supervisory
Restoral Reporting Code when the problem is corrected.
Maintenance Alarm Reporting Codes ............. Section [43]
Maintenance Restoral Reporting Codes ........ Section [44]
AC Failure Communication Delay ................... Section [62]
5.7.8 Test Transmissions
The panel can be programmed to transmit a Periodic Test
Transmission Reporting Code
(see Section 5.13 – “Test(see Section 5.13 – “Test
(see Section 5.13 – “Test(see Section 5.13 – “Test
(see Section 5.13 – “Test
Transmissions”)Transmissions”)
Transmissions”)Transmissions”)
Transmissions”)
, a System Test Reporting Code
(see(see
(see(see
(see
Section 3.4 – “[Section 3.4 – “[
Section 3.4 – “[Section 3.4 – “[
Section 3.4 – “[
✱✱
✱✱
✱
] [6] User Functions”] [6] User Functions”
] [6] User Functions”] [6] User Functions”
] [6] User Functions”
) or a LINKS 1000
Test Transmission Reporting Code
(see Section 5.23 –(see Section 5.23 –
(see Section 5.23 –(see Section 5.23 –
(see Section 5.23 –
“LINKS 1000 Cellular Communicator”).“LINKS 1000 Cellular Communicator”).
“LINKS 1000 Cellular Communicator”).“LINKS 1000 Cellular Communicator”).
“LINKS 1000 Cellular Communicator”).
Test Transmission Reporting Codes............... Section [46]
5.7.9 Miscellaneous
If the panel fails to transmit information to the central station,
it will display a Failure To Communicate (FTC) trouble
condition. The panel will transmit a Phone Number 1 Failure
to Communicate Reporting Code or a Phone Number 2
Failure to Communicate Reporting Code the next time it
calls the central station. The panel will transmit the old
events, followed by the FTC message, followed by the new
events. This will allow central station to determine which
events are old or new.
If the Event Buffer is uploaded or printed on-site on a regular
basis, an Event Buffer 75% Full Reporting Code can be
transmitted to warn that the buffer is almost full. This code is
good for use with the PC5400 Printer Module.
The General Zone Fault Alarm Reporting Code is sent
whenever a DEOL hardwired zone is shorted out. The
faulted zone will also be displayed in the Trouble section.
The General Zone Fault Restoral Reporting Code will be
sent when the problem zone is repaired.
The Delinquency Reporting Code is sent whenever the
panel is not armed within the number of days programmed
for the Delinquency Transmission Delay.
Miscellaneous Maintenance Reporting CodesSection [45]
Delinquency Transmission Delay .................... Section [62]
If the Delinquency Tx Delay is set for 1 day, there
must be 24 hours of no arming or disarming before
the Delinquency Code will be sent.
After a Delinquency Code has been transmitted, it
will not send again until the system has been armed
and disarmed.
5.8 Communicator – Reporting Formats
Each central station communication phone number can be
programmed to report using any one of the 4 formats
available. A 20 BPS pulse format is supported in addition to
Contact ID, SIA and a Pager format.
Communicator Format Options ....................... Section [50]
Communicator Call Directions ............ Section [51] to [55]
The following is a description of each reporting format:
5.8.1 Pulse Formats
Depending on which pulse format is selected, the panel will
communicate using the following specifications: