Digital Security Controls PC1575 Especificaciones Pagina 7

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 16
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 6
Escort4580
Voice Prompt
Security & Building
Automation Control Module
Turns any touch tone phone
into a fully functional keypad with
both Global and Partition control
Module contains extensive
library of voice prompts for security
and building automation control and
status feedback
Up to 6 words per voice prompt,
chosen from a 241 word library
Built-in Power Line interface for
up to 32 X-10 control devices
Program event activation of X-10
devices using up to 16 schedules
Automation
POL-C1CN
PC4010/4010CF
16 modules/system
32 readers total
1000 access cards
PC4020/4020CF
16 modules/system
32 readers total
1,000 access cards
Full standalone operation
Arm/disarm partitions & postpone
auto-arm by access card or access card
and code…from outside the protected
space
3 low current outputs per door
4 inputs per door…door contact,
request-to-exit input, arm, postpone
auto-arm
64 access levels
99 seven-day schedules
4 holiday groups - 730 holidays
Individual door-unlock schedules
Program via keypad, or via computer
with DLS-2 downloading software
1.5A regulated power supply
Power capacity per door:
reader - 125mA max. @ 5VDC
or 250mA max. @ 12VDC
lock - 250mA max. @ 12VDC
Auxiliary power -125mA @ 12VDC
Battery required - 12VDC, 7.0AH
Transformer req’d - 16.5VAC, 40VA
Fully supervised
Multiple Reader Technologies
• 26 bit standard Wiegand…plus
Polaris…Mag-Stripe Readers/Cards
POL-1 .................... Reader – indoor
POL-1W ................ Reader – outdoor
POL-2 .................... Reader & keypad – indoor
POL-2W ................ Reader & keypad – outdoor
POL-C1CN .............. Mag-stripe card
ShadowProx…Proximity Readers/Cards
SH-VR.................... Std size reader. – indoor/outdoor
SH-1 ...................... Slim-line mullion size reader
4" (10cm) range – indoor/outdoor
SH-2 ...................... Wall-switch size reader
4" (10cm) range – indoor/outdoor
SH-5 ...................... Reader 16" (40cm) range – indoor
SH-5EXT................ Reader 16" (40cm) range – outdoor
SH-C1 .................... Proximity card
SH-K1.................... Proximity keytag
HID…Proximity Readers/Cards
HID-MP5365.......... Slimline reader
4-5" (10-13cm) range – indoor
HID-PR5355 .......... Reader 5-9" (13-23cm) range
– indoor/outdoor
HID-PR5355KP.. .... Reader w/keypad 5-9"
(13-23cm) range – indoor/outdoor
HID-C1325KSF ...... Proximity card
HID-C1345KSF ...... Proximity keytag
POL-1
SH-2
SH-C1
SH-VR
SH-K1
Access
Control
PC4820
Two Reader Access Control Module
Integrated
SYSTEMS
Technology
HID-PR5355KP
T.Rex…Infrared Exit Detectors
KT-TREX-XL ...... Complete with piezo buzzer & tamper
KT-TREX-LT........ No piezo, no tamper
S Y S T E M
®
®
Security Products
MAXMAXSSYYSS
• 11 •• 10 •
Up to 550mA @ 12VDC power for:
- COMBUS power - local input devices
- local output signals
4 form 'C' programmable relays
- contacts rated for 2A @ 30VDC
59 programmable output options
Supervised for low/disconnected battery,
AC power fail, and aux. supply fault
PT1016 transfmr. incl…16VAC, 40VA
PC4052CR cabinet, red
Space for one additional PC4108A module
Space for two 7AH gel-cell batteries
PC4010CF...... up to 16 modules per
system for 64 relays total
PC4020CF...... up to 16 modules per
system for 64 relays total
PC4612
12 Zone Fire Annunciator
point annunciation of…
- 10 fire zones
- 2 supervisory zones
- common zone trouble
- common bell trouble
- system trouble
- AC ON LED
2 alarm notification circuits
- rated for 1.8A @ 24VDC - FWR
Outputs supervised for opens, shorts,
and ground fault
Self-restoring short circuit protection
PT1024 transfmr incl…28VAC, 160VA
PC4052CR cabinet, red
Space for two 4AH gel-cell batteries
PC4010CF ...... 4 panels/system
for 8 bell output zones total
PC4020CF ...... 4 panels/system
for 8 bell output zones total
All the security features of the
PC4010/4020 plus additional fire
features…
PC4701 Fire Module:
one 2-wire Class B/StyleB
supervised smoke zone
one Class B/StyleB
waterflow zone
dual supervised digital alarm
communicator outputs
common fire alarm & fire
trouble relays, form 'C', 2A,
30VDC contacts
All panel & expansion zones are
configurable for: fire, waterflow,
or fire supervisory
16VAC, 40VA transformer
PC4010CF/4020CF
Fire Control Panels
Identical to the standard security keypads
but with…red bezels
LCD4520/4521
Plain Language Keypads
UL/ULC Listed Fire Systems*
External battery charger c/w:
PC4055CR cabinet, red
PS4085 multi-rate charger module
PT1012 transformer…12VAC, 160VA
Space for 60 AH lead-acid battery
PS4350R
Fire System External Battery Charger
Advanced
Communications
4 communications formats…
high speed pulse (1400 &
2300 bps), Contact ID, and SIA
Digital
Fully compatible with the
Links2150
& Links2450
radio
transmitters
Long Range Radio
Alternate function of PC4400
module
DVACS
Fully compatible with Sur-Gard’s
Links1000
cellular transmitter
and SKYROUTE
cellemetry
transmitter
Wireless Communications
PC4702BP
Dual Bell Zone Panel
PC4204CF
Power Supply/Quad Relay Output Panel
3 built-in pager formats
Event-Initiated Paging
7438 C5
Vista de pagina 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 15 16

Comentarios a estos manuales